Use of 9.3µm CO2 Laser for Removal of Zirconia Restorations
1 MIN READ
Use of 9.3µm CO2 Laser for Removal of Zirconia Restorations
By Open Access Journal of Dental Sciences (OAJDS) on October 07, 2021
Call G, Kugel G, Jain S, Tran D, Dunn K and Papathanasiou A
ABSTRACT (Click Here for Full Study)
Objective
The primary aim of this study was to test if a 9.3µm Carbon Dioxide (CO2) laser could be used to effectively separate a cemented zirconia restoration from dentin. The secondary aim was to compare shear bond strength (SBS) between RelyXTM Unicem 2 Automix Cement (3M ESPE) (RelyXTM Unicem 2) and RelyXTM Luting Plus Automix Cement (3M ESPE) (RelyX™ Luting Plus).
Methods
40 teeth were prepared to expose dentin and then randomized into four groups of 10 samples. Zirconia slices (non-glazed Yttrium stabilized zirconia samples (2.5 x 3 x 1.5 mm)) were sandblasted with 50 micron aluminum oxide at 30 psi and then cemented onto the dentin samples with RelyX™ Unicem 2 or RelyX™ Luting Plus, dependent on the group. The cements were applied to both the zirconia and dentin with a force of 20 g/mm2 for 30 seconds following manufacturer’s recommendations. After 48 hours, the 9.3µm CO2 laser was used on half the samples for 5 seconds. All 40 zirconia samples were removed with the Instron 5566A in a traditional SBS test. The groups were: 1A - RelyX™ Unicem 2 and Laser, 1B - RelyX™ Unicem 2 and Shear Bond, 2A - RelyX™ Luting Plus and Laser, and 2B - RelyX™ Luting Plus and Shear Bond. The Mann–Whitney U test was used for comparison.
Results
Mean SBS of four groups ranged from 0.5 to 4.4 MPa. There was a significant difference in the SBS between 9.3µm CO2 laser and Shear Force methods for RelyX™ Luting Plus. However, the difference between the two methods was not significant for RelyX Unicem 2. RelyX™ Unicem 2 provided significantly higher SBS than RelyX™ Luting Plus for both the CO2 laser and shear force methods (Table 2).
Conclusions
The 9.3µm CO2 laser effectively separated the zirconia restoration cemented with RelyX™ Luting Plus from dentin. RelyX™ Unicem 2 provided significantly stronger SBS than RelyX™ Luting Plus.
Call G, et al. Use of 9.3µm CO2 Laser for Removal of Zirconia Restorations. J Dental Sci 2021, 6(4): 000312.